Indian Structural Columns are vertical structural members designed to transfer loads from upper portions of a structure to its foundation or supporting members. They are an important part of structural steel frameworks used in buildings, industrial facilities, warehouses, infrastructure and engineering structures.
Structural columns are selected according to factors such as load-bearing requirements, column height, section properties, dimensions, material grade, connection design and applicable project specifications. The appropriate section helps provide the required strength and stability within the overall structural system.
Depending on the structural design, different steel column sections can be incorporated into building frames, industrial structures, equipment-support systems and other fabricated assemblies. Structural columns can also be used together with beams, channels, angles and hollow sections to create complete steel frameworks.
At Moksh Tubes & Fittings LLP, we support requirements for Indian Structural Columns based on customer and project specifications. Customers can provide the required column section, dimensions, material grade, length, quantity and applicable Indian Standard for procurement enquiries.
Indian Structural Columns are suitable for both standard and project-based requirements across construction, industrial, infrastructure and engineering applications, subject to the specified product and design requirements.
Get the complete Indian Structural Columns datasheet with chemical composition, mechanical properties, heat treatment details, and applications. Enter your email to receive the PDF instantly.
We respect your privacy. Your email will only be used to send the datasheet.
Indian Structural Columns are available in different section sizes, depths, flange dimensions, thicknesses, lengths and structural steel grades according to applicable Indian Standards and project requirements. The appropriate column section is selected based on the required load-bearing capacity, structural design, column height, connection requirements and intended application.
| Category | Details |
|---|---|
| Product | Indian Structural Columns |
| Profile | I-Section / H-Section / Structural Column Sections |
| Material | Structural Steel / Carbon Steel |
| Types | Structural Column Sections as per applicable IS specifications |
| Standards | Applicable Indian Standards / Project Specifications |
| Grades | As per applicable material specification |
| Section Depth | Various standard sizes |
| Flange Width | As per selected column section |
| Web Thickness | As per selected section |
| Flange Thickness | As per selected section |
| Length | Standard Lengths / Cut-to-Length |
| Surface | Mill Finish / As Specified |
| Supply Form | Individual Sections / Bundles |
| Customization | Size, thickness, length and grade as required |
| Applications | Buildings, Industrial Structures, Warehouses, Infrastructure & Engineering |
Indian Structural Columns are available in different section depths, flange widths, web thicknesses, flange thicknesses and unit weights. The appropriate column section is selected according to structural design, loading conditions, column height and applicable Indian Standard.
| Section | Size (mm) | Web Thickness (mm) | Flange Thickness (mm) | Weight (kg/m) |
|---|---|---|---|---|
| SC 100 | 100 × 100 | 6.0 | 10.0 | 19.97 |
| SC 120 | 120 × 120 | 6.5 | 11.0 | 26.22 |
| SC 140 | 140 × 140 | 7.0 | 12.0 | 33.25 |
| SC 150* | 152 × 152 | 7.9 | 11.9 | 36.93 |
| SC 160 | 160 × 160 | 8.0 | 13.0 | 41.85 |
| SC 180 | 180 × 180 | 8.5 | 14.0 | 50.48 |
| SC 200 | 200 × 200 | 9.0 | 15.0 | 60.24 |
| SC 220 | 220 × 220 | 9.5 | 16.0 | 70.41 |
| SC 250 | 250 × 250 | 10.0 | 17.0 | 85.54 |
| Section | Size (mm) | Web Thickness (mm) | Flange Thickness (mm) | Weight (kg/m) |
|---|---|---|---|---|
| HB 150 | 150 × 150 | 5.4 | 9.0 | 27.06 |
| HB 150* | 150 × 150 | 8.4 | 9.0 | 30.15 |
| HB 150* | 150 × 150 | 11.8 | 9.0 | 33.66 |
| HB 200 | 200 × 200 | 6.1 | 9.0 | 37.31 |
| HB 200* | 200 × 200 | 7.8 | 9.0 | 39.73 |
| HB 225 | 225 × 225 | 6.5 | 9.1 | 43.12 |
| HB 225* | 225 × 225 | 8.6 | 9.1 | 46.52 |
| HB 250 | 250 × 250 | 6.9 | 9.7 | 50.98 |
| HB 250* | 250 × 250 | 8.8 | 9.7 | 54.41 |
| HB 300 | 300 × 250 | 7.6 | 10.6 | 58.74 |
| HB 300* | 300 × 250 | 9.4 | 10.6 | 62.67 |
| HB 350 | 350 × 250 | 8.3 | 11.6 | 67.42 |
| HB 350* | 350 × 250 | 10.1 | 11.6 | 72.03 |
| HB 400 | 400 × 250 | 9.1 | 12.7 | 77.43 |
| HB 400* | 400 × 250 | 10.6 | 12.7 | 81.83 |
| HB 450 | 450 × 250 | 9.8 | 13.7 | 87.22 |
| HB 450* | 450 × 250 | 11.3 | 13.7 | 92.19 |
Indian Structural Columns can be supplied in different structural steel grades according to the applicable Indian Standard and project requirements. The selected grade depends on the required mechanical properties, structural loading, column design, fabrication requirements and intended application.
At Moksh Tubes & Fittings LLP, Structural Columns can be sourced according to the customer's specified grade, section, dimensions, length, quantity and applicable standard, subject to product availability.
| Grade / Specification | Material Type | Typical Requirement |
|---|---|---|
| IS 2062 | Structural Steel | General structural and engineering applications |
| E250 | Structural Steel | General structural and fabrication applications |
| E350 | Structural Steel | Applications requiring higher specified strength |
| Other Grades | Structural Steel | As per project specification and requirement |
Indian Structural Columns are widely used in construction, industrial structures, infrastructure, fabrication and engineering projects where vertical load-bearing and structural support are required.
Structural columns are important load-bearing members in building structures and steel frameworks. Common applications include building structural frameworks, commercial and industrial buildings, steel-framed structures, supporting members, and structural connections and assemblies.
Indian Structural Columns are used in industrial facilities where strong vertical structural members are required. Applications include industrial sheds, factory structures, warehouses, equipment support structures, and heavy-duty structural frameworks.
Structural columns can be used as vertical supporting members in warehouse and storage facilities. Applications include warehouse frameworks, storage structures, roof-support systems, and steel building structures.
Structural columns can be incorporated into infrastructure and civil engineering projects where the specified column section meets the design requirements. Applications include infrastructure frameworks, elevated structures, supporting structures, platforms, and engineering structures.
Structural columns are suitable for fabrication of heavy steel frameworks and assemblies. Applications include structural frames, support structures, heavy fabricated assemblies, industrial platforms, and steel frameworks.
Structural columns can be used as part of supporting frameworks for industrial machinery and equipment where the selected section meets the required structural design.
Indian Structural Columns are used in various engineering applications requiring vertical steel support members with specified structural properties.
Structural columns can be combined with beams, channels, angles and hollow sections to create complete steel building and industrial frameworks.
Structural columns can be combined with beams, channels, angles and hollow sections to create complete steel building and industrial frameworks.
The appropriate column section, dimensions and grade should always be selected according to the structural loading, column height, stability requirements, applicable Indian Standard and project specifications.
Indian Structural Columns are widely used as vertical load-bearing and supporting members in construction, industrial, infrastructure and engineering applications.
The appropriate column section, dimensions, grade and length should be selected according to the structural loading, column height, stability requirements, applicable Indian Standard and project specifications.
Indian Structural Columns provide a reliable solution for vertical load-bearing, structural support and steel framework applications across construction, industrial, infrastructure and engineering projects.
Suitable for vertical structural support when the appropriate section is selected according to the engineering design.
Properly selected column sections provide the required strength and rigidity for structural frameworks.
Appropriate sections can be selected for industrial buildings, warehouses and other heavy structural applications.
Suitable for buildings, industrial structures, warehouses, infrastructure, platforms and engineering projects.
I-shaped, H-shaped and other applicable structural column sections can be selected according to project requirements.
Different section depths, flange widths and thicknesses allow engineers to select a suitable column section for the structural design.
Can be combined with beams, channels, angles and hollow sections to form complete steel frameworks.
Suitable for common fabrication operations such as cutting, drilling, welding and assembly, subject to applicable specifications.
Structural steel grades can be selected according to required mechanical properties and project specifications.
The appropriate column section should always be selected according to the structural loading, column height, stability requirements, section properties, applicable Indian Standard and project specifications.
(Typical minimum values as per IS 2062:2011; values vary with material thickness and quality/sub-grade.)
| Standard / Grade | IS 2062 E250 | IS 2062 E350 | IS 2062 E410 | IS 2062 E450 |
|---|---|---|---|---|
| Yield Strength (MPa), ≤20 mm | 250 | 350 | 410 | 450 |
| Yield Strength (MPa), 20–40 mm | 240 | 330 | 390 | 430 |
| Yield Strength (MPa), >40 mm | 230 | 320 | 380 | 420 |
| Tensile Strength (MPa), Min. | 410 | 490 | 540 | 570 |
| Elongation (%), Min. | 23 | 22 | 20 | 20 |
Moksh Tubes & Fittings LLP supports customers looking for Indian Structural Columns for construction, industrial, infrastructure, fabrication and engineering requirements. Our supply approach is based on the customer's required column section, dimensions, grade, length, quantity and applicable specifications.
Indian Structural Columns are structural steel sections primarily used as vertical load-bearing and supporting members in buildings, industrial structures, warehouses, infrastructure and engineering projects.
Structural Columns are commonly used in steel building frameworks, industrial sheds, warehouses, supporting structures, platforms, infrastructure projects and heavy fabrication.
Structural Columns can include different I-shaped, H-shaped and other applicable structural column sections, depending on the Indian Standard and project requirements.
Structural Columns can be supplied according to the applicable Indian Standard or project specification. The exact standard should be confirmed according to the required section and application.
Grades such as IS 2062, E250 and E350 may be considered according to the applicable specification and product availability. Exact grade availability should be confirmed at the time of enquiry.
Looking for Indian Structural Columns for your construction, industrial, infrastructure or fabrication project?
Contact Moksh Tubes & Fittings LLP for Structural Column requirements based on your required column section, dimensions, grade, length and quantity.
Share your project specifications, drawings or material requirements with our team to discuss the suitable Indian Structural Columns for your application.
📞 Contact Moksh Tubes & Fittings LLP at +91 97695 84950 for product availability, technical specifications and quotation enquiries.